CCH-HP10
220V±10%, 50/60Hz
30W
10L/h
1.5-2L/min
30KG
540*400*500mm
1-3μs/cm
18.2MΩ/cm/18.2 MOhm-cm
Availability: | |
---|---|
Quantity: | |
RO Pure Water EDI Ultra-pure Water System Lab Reagent Grade Water System
Ultrapure water system use the pretrement, reverse osmosis technology, super purification processing and later stage processing method .it almost completely remove water conduction medium and also remove water dissociation of colloidal substance, gas and organic compounds to ver low degree .
Product Features
1. The system is equipped with low water pressure and anhydrous protection signal device, which has the functions of low water pressure alarm, water cut-off and power failure, and automatic protection of water tank.
2. It has PLC control panel touch screen, which shows the flow monitoring filter element replacement cycle such as water filtering, anhydrous and consumables replacement reminder alarm function, and English display filter element replacement information.
3. RO and up water quality online monitoring and water temperature online monitoring.
ultra pure water system internal circulation setting, so that the ultra pure water produce high purity water quality.
4. The system operates automatically. The system working status is reported in real time, and the large LCD animation display makes it easier to use.
5. Users can freely set water quality parameters, and the system can display a variety of water quality parameters.
6. The system runs without heat, noise. The performance parameters are adjustable, which is suitable for different water sources.
7. The system has the function of dispensing pure water and ultrapure water at the same time, and the function of dispensing water with required quality and quantity.
8. It has two modes of circulation and direct water supply to prevent the breeding of bacteria in the pipeline system.
RO Pure Water EDI Ultra-pure Water System Lab Reagent Grade Water System
Ultrapure water system use the pretrement, reverse osmosis technology, super purification processing and later stage processing method .it almost completely remove water conduction medium and also remove water dissociation of colloidal substance, gas and organic compounds to ver low degree .
Product Features
1. The system is equipped with low water pressure and anhydrous protection signal device, which has the functions of low water pressure alarm, water cut-off and power failure, and automatic protection of water tank.
2. It has PLC control panel touch screen, which shows the flow monitoring filter element replacement cycle such as water filtering, anhydrous and consumables replacement reminder alarm function, and English display filter element replacement information.
3. RO and up water quality online monitoring and water temperature online monitoring.
ultra pure water system internal circulation setting, so that the ultra pure water produce high purity water quality.
4. The system operates automatically. The system working status is reported in real time, and the large LCD animation display makes it easier to use.
5. Users can freely set water quality parameters, and the system can display a variety of water quality parameters.
6. The system runs without heat, noise. The performance parameters are adjustable, which is suitable for different water sources.
7. The system has the function of dispensing pure water and ultrapure water at the same time, and the function of dispensing water with required quality and quantity.
8. It has two modes of circulation and direct water supply to prevent the breeding of bacteria in the pipeline system.
Model | CCH-HP10 |
Output | 10L/h |
Flow rate | 1.5-2L/min |
Feed water requirements | Tap water, temperature 5~45℃, pressure:0.15-0.35Mpa; conductivity<400μs/cm |
RO water quality | |
Conductivity(25℃) | 1-3μs/cm |
Ion rejection rate | 99%(new RO membrane) |
Organic rejection rate | >99%,when MW>200g/mol |
Particles and bacteria rejection rate | >99% |
Ultrapure water quality | |
Resistivity(25℃) | 18.2MΩ/cm |
Heavy metal element | <0.01 |
Metal cation content (ppb) | Fe<0.005, Cu<0.005, Al<0.005, Ni<0.005, Zn<0.02, Cr<0.005, Na<0.01, K<0.02≤0.01 |
Metal anion content (ppb) | C1-<0.01, N -<0.02, NO<0.02, SO<0.01 |
Bacteria content | <1pc/ml |
Bateria | <1CFU/ml |
Particle | >0.2um/ml<1um/ml |
Endotoxin | <0.001EU/ml |
TOC | 1-3ppb |
AC requirement | 220V±10%, 50/60Hz |
Power | 30W |
Dimension(L*W*H-mm) | 540*400*500mm |
Weight(kg) | 30 |
Standard configuration | Main body, pressure tank |
Model | CCH-HP10 |
Output | 10L/h |
Flow rate | 1.5-2L/min |
Feed water requirements | Tap water, temperature 5~45℃, pressure:0.15-0.35Mpa; conductivity<400μs/cm |
RO water quality | |
Conductivity(25℃) | 1-3μs/cm |
Ion rejection rate | 99%(new RO membrane) |
Organic rejection rate | >99%,when MW>200g/mol |
Particles and bacteria rejection rate | >99% |
Ultrapure water quality | |
Resistivity(25℃) | 18.2MΩ/cm |
Heavy metal element | <0.01 |
Metal cation content (ppb) | Fe<0.005, Cu<0.005, Al<0.005, Ni<0.005, Zn<0.02, Cr<0.005, Na<0.01, K<0.02≤0.01 |
Metal anion content (ppb) | C1-<0.01, N -<0.02, NO<0.02, SO<0.01 |
Bacteria content | <1pc/ml |
Bateria | <1CFU/ml |
Particle | >0.2um/ml<1um/ml |
Endotoxin | <0.001EU/ml |
TOC | 1-3ppb |
AC requirement | 220V±10%, 50/60Hz |
Power | 30W |
Dimension(L*W*H-mm) | 540*400*500mm |
Weight(kg) | 30 |
Standard configuration | Main body, pressure tank |
Laboratory water purification system can directly purify municipal tap water into high-quality water. The standard is applied to the inspection and analysis of clinical biochemical analyzer, immunity, PCR, blood gas analyzer, capillary electrophoresis instrument, microbial culture, reagent preparation, volumetric cleaning and so on. It meets the secondary water quality requirements in the national standards GB / T6682-2008, ASTM, DINIS03696 and NCCLS. It is an affordable ultrapure water system for hospital laboratory.
Features
1. Intelligent integrated circuit control board, full-automatic continuous water production, power on self-test, water shortage protection alarm, power failure automatic protection, RO membrane automatic flushing, etc.
2. Online detection of water quality resistance value, real-time on-line display on LCD screen, simple consumables.
3. No noise, low power, easy operation, adjustable performance parameters.
4. Full automatic control of water tank, integrated structure of reverse osmosis system.
Scope of Application
1. Inspection and Analysis, Reagent Preparation, Microbial Culture, Container Cleaning, etc. Through the addition device, it can be applied to clinical immunity, enzyme labeling test and so on.
2. Inspection Water, fully supporting the use of various brands of automatic biochemical instruments: Olympus, Beckman, KHB, Mindray, Roche, Toshiba, Rayto, Dirui, etc.
Application Area
It is widely used in inspection and R&D laboratories in universities, hospitals, enterprises, administrative testing institutions, metallurgy, non-ferrous metals, chemical industry, cosmetics, medicine and health, food, beverage, beer, tobacco and other industries.
Laboratory water purification system can directly purify municipal tap water into high-quality water. The standard is applied to the inspection and analysis of clinical biochemical analyzer, immunity, PCR, blood gas analyzer, capillary electrophoresis instrument, microbial culture, reagent preparation, volumetric cleaning and so on. It meets the secondary water quality requirements in the national standards GB / T6682-2008, ASTM, DINIS03696 and NCCLS. It is an affordable ultrapure water system for hospital laboratory.
Features
1. Intelligent integrated circuit control board, full-automatic continuous water production, power on self-test, water shortage protection alarm, power failure automatic protection, RO membrane automatic flushing, etc.
2. Online detection of water quality resistance value, real-time on-line display on LCD screen, simple consumables.
3. No noise, low power, easy operation, adjustable performance parameters.
4. Full automatic control of water tank, integrated structure of reverse osmosis system.
Scope of Application
1. Inspection and Analysis, Reagent Preparation, Microbial Culture, Container Cleaning, etc. Through the addition device, it can be applied to clinical immunity, enzyme labeling test and so on.
2. Inspection Water, fully supporting the use of various brands of automatic biochemical instruments: Olympus, Beckman, KHB, Mindray, Roche, Toshiba, Rayto, Dirui, etc.
Application Area
It is widely used in inspection and R&D laboratories in universities, hospitals, enterprises, administrative testing institutions, metallurgy, non-ferrous metals, chemical industry, cosmetics, medicine and health, food, beverage, beer, tobacco and other industries.