1. Working Principle


The hypochlorous acid generator adopts a diaphragm free electrolytic cell to electrolyze the special electrolyte. The chloride ion in the electrolyte on the anode is oxidized to generate chlorine.

 2CL-CL2+2e-

Chlorine generated on anode reacts with the water to generate hypochlorite.

 CL2+H 20HCLO+HCL


7

2. Sterilization Principle


Hypochlorous acid (HCIO) produced by electrolysis has strong oxidation ability. It can damage the cell membrane after contacting with microorganisms, so that the protein, RNA and DNA in cells cannot play their normal biochemical activities, quickly destroy the cell membrane of harmful microorganisms, and lead to the death of microorganisms to achieve the sterilization effect.


3. Main Bactericidal Factors and Intensity


Main bactericidal factor: hypochlorous acid (HCIO)

Hypochlorite water can kill many kinds of microorganisms, such as bacterial propagules, viruses, fungi, etc. Suspension quantitative killing test showed that the logarithm of killing Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans by suspension was more than 5 after 1 min.


Hunan Moreshine Trading Co.,Ltd

QUICK LINKS

PRODUCTS CATEGORY

CONTACT US

    Add : 204, Building 2, Xinggong Science And Technology Park, Luyun Road, High-Tech Development Zone,Changsha,Hunan Province,China
    Phone : +86-18075169174
    E-mail : info@labequipmachine.com
    Tel : +86-731-83979221
LINKS:      Labpuriwater               Labpuriwater                  Labpuriwater                 Labpuriwater                  Labpuriwater
Copyright  2022 Hunan Moreshine Trading Co.,Ltd.Technology by Leadong. Sitemap.